The primary purpose of cleaning surgical instruments is to remove all inorganic and organic bioburden material from the internal and external surfaces cleaning surgical instruments inside and out with careful attention to cleaning cannulated surgical instruments. The secondary purpose of cleaning surgical instruments is to maintain and improve the passive Layer of stainless steel. The passive layer is provided by the manufacturer of the surgical instruments, within the surgical stainless steel, to resist prevent corrosion. Proper cleaning of the surgical instrument will maintain and improve this passive layer. Prevent Corrosion If the manual cleaning, brushing and rinsing steps are not properly carried out, protein debris can harden and lead to formation of biofilm on the biopsy channel of the endoscope. The optimal cleaning protocol will break down bioburden and clean the surface. Inadequate cleaning can result in material remaining on the surgical instrument or endoscope surfaces which prevents disinfection and sterilization fluids or gases reaching all parts of potentially contaminated surfaces. Inadequate sterilization or disinfection may in turn result in transmission of infectious organisms when the endoscope is reused. The intricate design, delicate materials and susceptibility to damage of flexible endoscopes further complicates their decontamination.
Cleaning Surgical Instruments is the Prerequisite for Sterilization
All disinfection processes, whether done manually or done automatically in a washer decontaminator disinfector, can only be effective if prior cleaning is adequate. Effective disinfection or sterilization of an inadequately cleaned surgical instrument or scope is not possible. Endoscopes should be cleaned with an enzymatic detergent compatible with the endoscope immediately after use and before manual or automated disinfection. Cleaning involves the entire endoscope, including valves, working channels, connectors and all detachable parts. High level enzymatic formulations Enzymatic Surgical Instrument Cleaners, in combination with a high level surfactant chemical complex, have been shown to be more effective in removing stains, hard water deposits, and encrusted bioburden, while being safe to use for rigid or flexible scopes.
Ultrasonic Surgical Instrument Cleaner Solution  
Surgical Instrument Cleaning Detergents
Enzyme Cleaning Concentrates Enzymes are effective and they are costly
Manufacturers usually recommend that Enzyme Cleaning concentrates should be discarded after each use as these products are not microbicidal and will not retard microbial growth. Some manufactures of combination or all-in-one cleaning concentrates include a bacteriostatic agent which will prevent the growth of microorganisms.
Optimal Temperature for Cleaning Surgical Instruments with Enzyme Cleaning Concentrates
Enzyme cleaning concentrates function more effectively at temperatures above room temperature. The optimal range begins as > 22C - 72°F with performance reaching it's peak at 58.3C - 137F. This is often referred to as the optimal temperature for the performance or activity of enzymatic action. The activity of enzymes does not stop at higher temperatures but the level of performance does begin to decrease. Enzyme cleaning concentrates enzyme-detergents and all-in-one cleaning concentrates, which include enzymes, should be used in accordance with the manufacturer's recommendations and the recommendations of the medical devices being cleaned.
Cleaning Surgical Instruments and pathological prions
Creutzfeld-Jakob disease deactivating prions approach is the same if the presence of pathological prions including the prions of vCJD Creutzfeld-Jakob disease is suspected, however attention to detail is more important. It has been long known, that prions are unusually resistant to disinfection and sterilization by physical and chemical methods in common use for decontamination of infectious pathogens. It is a difficult task to gain a consensus opinion on what constitutes optimal and practical conditions for decontamination of prions. Numerous studies have been conducted, but they do not reflect the reprocessing procedures for surgery instruments in a clinical setting which are critical for iatrogenic transmission. 
Surgical Instrument Cleaning Detergent Enzymes Lubricant Cleaners
Buy Surgical Instrument Detergent Enzymes Lubricant Cleaners
Buy Surgical Instrument Detergent Enzymes packaged as:
UPS-23  easy-FOAM-it Pre wash Surgical Instrument Detergent Enzymes 12 per case,
UPS-1 all-in-ONE Surgical Instrument Detergent Enzyme Cleaners 4 gallons,
UPS-5 Surgical Instrument Detergent Enzyme Cleaners 5 gallon,
UPS-15 Surgical Instrument Detergent Enzyme Cleaners 15 gallon,
UPS-30 Surgical Instrument Detergent Enzyme Cleaners 30 gallon,
UPS-55 Surgical Instrument Detergent Enzyme Cleaners 55 gallon, and
Washer Disinfector Detergents are packaged as described above.
The all-in-ONE Surgical Instrument Cleaning Detergents will lower your cleaning costs and replace multiple Surgical Instrument Cleaning products for Ultrasonic Surgical Instrument Cleaner Solutions, Cleaning Surgical Instruments, Surgical Instrument Care, Cleaning Surgical Instruments and Cleaning Eye Surgical Instruments. Ultrasonic cleaning of reusable endoscope accessories and components may be needed to remove material from hard-to-clean areas. The same detergent used for ultrasonic cleaning can be the same as used for manual cleaning. Recommendations for detergents used for ultrasonic cleaning are as follows: a non-foaming detergent must used the labeling of the detergent should recommend the use of the product for ultrasonic cleaning always use enzymatic detergents for instruments soiled with bioburden protein, fats, starch use detergents with surfactant cleaning agents for removing stains and hard water mineral deposits the treatment cleaning time recommended by the medical device and detergent manufacturers should be observed avoid the inhalation of enzyme-containing detergent aerosols risk of anaphylactic reactions by maintaining a cover over the ultrasonic cleaner when in use.
Ultrasonic Surgical Instrument Cleaner Solution  
Surgical Instrument Cleaning Detergents
Ultrasonic cleaners are very effective when used with hot water per manufacturers recommended temperature and specially formulated detergents. It is recommended that all visible debris and blood be removed from the instrument prior to ultrasonic cleaning.  Sort instruments by similar metals to prevent corrosion due to the contact of dissimilar metals. electrolytic deposition  galvanic corrosion It is not recommended to clean plated instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp instruments may crack or rupture the plating. Because Ultrasonic Cleaners do not provide the complete proper sequence of treatment: final rinses that are purified, purged between treatments, and/or have temperatures elevated to disinfection levels, they are not considered to be as clinically effective as automated washer decontaminators  disinfectors. Ultrasonic Cleaning can effectively remove long term encrustation and surgical cements or glues that have dried onto instrumentation. Always refer to the printed manufacturer recommendations prior to using Ultrasonics.
Topics:
cleaning surgical instruments prior to sterilization,
surgical instrument cleaning process,
the highest quality surgical instrument cleaning solution,
products to develop the surgical instrument cleaning protocol,
Surgical Instrument Cleaning Solutions,
surgical instrument cleaning protocol,
reducing surgical instrument cleaning, and
surgical instrument cleaning detergent enzyme lubricant solutions.

cleaning surgical instruments prior to sterilization,
surgical instrument cleaning process,
the highest quality surgical instrument cleaning solution, and
products to develop the optimal surgical instrument cleaning protocol.
Surgical Instrument Enzymatic Surgical Instrument Cleaning Detergent
Surgical Instrument Cleaner with surface Conditioners
easy FOAM-it Surgical Instrument Cleaner
Surgical Instrument Washer Detergent
all-in-ONE Surgical Instrument Cleaning Deregent Product Description
For additional information go to: Surgical Instrument Detergents,
Washer Disinfector Detergents, and Endoscope Cleaners.
Contact us for surgical instrument washer disinfector detergents
Contact Customer Service: 1-509-220-2456, email: CustomerService@ergo-Logistics.com
Contact Product Support: 1-509-747-5027, email Temple@ergo-Logistics.com
Buy Surgical Instrument Detergents and surgical instrument cleaning detergents that cut costs.
Buy surgical instrument detergents that clean residue free.
Surgical instrument detergent enzyme lubricant cleaners cuts costs. SITEMAP
Surgical instrument detergent enzyme lubricant cleaners clean faster and clean residue free.
surgical instrument detergents, washer disinfector detergents, endoscope cleaning detergents
surgical instrument detergents, washer disinfector detergents, endoscope cleaning detergents
surgical instrument detergents, washer disinfector detergents, endoscope cleaning detergents
Endoscope Cleaning Solution Enzyme Detergents
Endoscope Cleaning Solution Enzyme Detergents
surgical instrument detergents, washer disinfector detergents, endoscope cleaning detergents